PB Heat
PB Heat Series WV-DV Direct Vent Oil-Fired Cast Iron Boiler, 105 to 182 MBH
PB Heat Series WV-DV Direct Vent Oil-Fired Cast Iron Boiler, 105 to 182 MBH
Series WV-DV Optional Equipment
View listOptional equipment PB Heat lists for this series. Check the items you need; they are added to the boiler's takeoff line with their PB Heat code numbers.
Couldn't load pickup availability
The PB Heat Series WV-DV is a residential, fully packaged, direct vent oil-fired cast iron hot water boiler with a large water content, wet-base section design and high efficiency sealed combustion flame retention burners. PB Heat lists it as ETL design certified.
Standard equipment (as listed by PB Heat):
- Cast iron sections, factory tested and assembled with steel push nipples
- Deluxe powder coated steel jacket
- Choice of Riello BF5 or Beckett NX burner
- Solid state burner control with pre- and post-purge
- Boiler reset control with LWCO
- Temperature-pressure gage; drain valve; 30 PSI safety relief valve
- Target wall; top cleanout; built-in air elimination baffle; full plate swing-out door; top flue outlet
- Concentric vent termination kit
- Taco 007 circulator
Each boiler includes a concentric vent termination kit (#91776) and a 10 ft flexible vent pipe kit (#91772). The 15 ft (#91773) and 20 ft (#91774) kits are supplied in lieu of the standard kit; select them in the Series WV-DV Optional Equipment checklist on this page. WPCT models include a tankless coil.
Ratings (as published by PB Heat):
| Model | Firing Rate GPH | Input MBH | Heating Capacity MBH | Net Water MBH | AFUE |
|---|---|---|---|---|---|
| WV-DV-03 | 0.75 | 105 | 92 | 80 | 86.7 |
| WV-DV-04 | 1.15 | 161 | 141 | 122 | 86.7 |
| WV-DV-04 | 1.30 | 182 | 158 | 137 | 86.0 |
Heating capacity and AFUE ratings are based on U.S. Government test.
Order codes (as listed by PB Heat):
| Model | Package | Burner | Code No. |
|---|---|---|---|
| WV-DV-03 | WPC: with circulator | Riello BF53 | 13388 |
| WV-DV-03 | WPC: with circulator | Beckett NX3 | 13330 |
| WV-DV-04 | WPC: with circulator | Riello BF54 | 13486 |
| WV-DV-04 | WPC: with circulator | Beckett NX4 | 13446 |
| WV-DV-03 | WPCT: with circulator and tankless coil | Riello BF53 | 13398 |
| WV-DV-03 | WPCT: with circulator and tankless coil | Beckett NX3 | 13332 |
| WV-DV-04 | WPCT: with circulator and tankless coil | Riello BF54 | 13488 |
| WV-DV-04 | WPCT: with circulator and tankless coil | Beckett NX4 | 13448 |
Included with each boiler (no charge): #91776 Concentric Vent Termination Kit and #91772 10 ft Flexible Vent Pipe Kit.
Lead time is confirmed when we quote.
Documents: Series WV-DV Catalog
Image is for illustration only. Refer to the product spec sheet for exact dimensions and configuration, and confirm with Kingsway Marketing LLC before you request a quote.
Product selection, sizing and code compliance remain the responsibility of the design professional and the authority having jurisdiction.
Share