PB Heat
PB Heat Series SC / SC(T) Semi-Commercial Power Burner Boiler, Oil, Gas or Gas/Oil, 392 to 794 MBH
PB Heat Series SC / SC(T) Semi-Commercial Power Burner Boiler, Oil, Gas or Gas/Oil, 392 to 794 MBH
Burner Equipment
Choices from this burner's own PB Heat page. Standard items are already included; change only what the job needs. Your selections are added to the boiler's SKU as one takeoff line.
Series SC / SC(T) Optional Equipment
View listOptional equipment PB Heat lists for this series. Check the items you need; they are added to the boiler's takeoff line with their PB Heat code numbers.
Couldn't load pickup availability
The PB Heat Series SC and SC(T) are semi-commercial cast iron power burner boilers, packaged or knockdown, with forced draft venting, for steam or hot water, with oil, gas or gas/oil burners. SC(T) models accept optional tankless coils. Sections are a factory assembled split block.
Ratings (as published by PB Heat):
| Size | Oil GPH | Oil Input MBH | Gas Input MBH | Gross Output MBH | Net Steam sq ft | Net Steam MBH | Net Water MBH | Boiler H.P. | Ship Wt (lb) |
|---|---|---|---|---|---|---|---|---|---|
| 05 | 2.80 | 392 | 404 | 327 | 1022 | 245 | 284 | 9.8 | 815 |
| 06 | 3.50 | 490 | 505 | 409 | 1278 | 307 | 356 | 12.2 | 910 |
| 07 | 4.00 | 560 | 577 | 468 | 1463 | 351 | 407 | 14.0 | 1005 |
| 08 | 4.50 | 630 | 649 | 527 | 1647 | 395 | 458 | 15.8 | 1100 |
| 09 | 5.00 | 700 | 722 | 586 | 1832 | 440 | 510 | 17.5 | 1195 |
| 10 | 5.50 | 770 | 794 | 645 | 2016 | 484 | 561 | 19.3 | 1280 |
PB Heat notes that net ratings are determined in accordance with ANSI/AHRI Standard 1500 test procedures; see the spec sheet for thermal and combustion efficiency.
Variants cover the boiler less burner and with each factory-matched burner listed by PB Heat (burner carton with standard UL operating mode). Packaged (factory assembled) construction, burner motor voltages, combustion controls, FM / CSD-1 operating modes and other burner options are available as options for each size. The domestic water coil and barometric draft dampers PB Heat lists for this series are in the Series SC / SC(T) Optional Equipment checklist on this page.
Burner models by size (as published by PB Heat; "n/a" means not offered):
| Burner | 05 | 06 | 07 | 08 | 09 | 10 |
|---|---|---|---|---|---|---|
| Oil: Beckett | CF500 | CF500 | CF800 | CF800 | CF800 | CF800 |
| Oil: Carlin | 201CRD | 201CRD | 201CRD | 201CRD | 301CRD | 301CRD |
| Oil: Power Flame CR | CR1-O | CR1-O | CR1-O | CR1-O | CR1-O | CR1-O |
| Gas: Beckett | CG10-24 | CG10-24 | CG10-24 | CG10-24 | CG10-24 | CG10-24 |
| Gas: Carlin | 301 GAS | 301GAS | 301GAS | 301GAS | 301GAS | 301GAS |
| Gas: Power Flame JR | JR15A-10 | JR15A-10 | JR15A-10 | JR30A-10 | JR30A-10 | JR30A-10 |
| Gas: Power Flame CR | CR1-G-10 | CR1-G-10 | CR1-G-10 | CR1-G-10 | CR1-G-10 | CR1-G-10 |
| Gas/Oil: Power Flame CR | CR1-GO-10 | CR1-GO-10 | CR1-GO-10 | CR1-GO-10 | CR1-GO-10 | CR1-GO-10 |
Lead time is confirmed when we quote.
Documents: Series SC Catalog | SC/SC(T) Suggested Specifications
Image is for illustration only. Refer to the product spec sheet for exact dimensions and configuration, and confirm with Kingsway Marketing LLC before you request a quote.
Product selection, sizing and code compliance remain the responsibility of the design professional and the authority having jurisdiction.
Share