PB Heat
PB Heat Series GM Cast Iron Gas Boiler, Complete Water Package, 215 to 399 MBH
PB Heat Series GM Cast Iron Gas Boiler, Complete Water Package, 215 to 399 MBH
Series GM Optional Equipment
View listOptional equipment PB Heat lists for this series. Check the items you need; they are added to the boiler's takeoff line with their PB Heat code numbers.
Couldn't load pickup availability
The PB Heat Series GM is a packaged residential/commercial cast iron hot water boiler with atmospheric gas spark ignition and natural draft venting, for natural or LP gas. It is offered as a complete water package (boiler with the required draft hood, trim and vent damper as listed by PB Heat).
Standard equipment (as listed by PB Heat):
- Cast iron sections, factory tested
- Deluxe powder coated steel jacket
- 30 PSI safety relief valve
- Spark ignition
- Drain valve and temperature-pressure gage (unmounted)
- Vertical draft hood; vent damper (GM-e-05 and GM-e-06; GM-07 and GM-08 ship less vent damper)
- Flame rollout and vent safety shutoff switches
- Boiler reset with LWCO
- Taco 0010 circulator (05-06 section) or Taco 0012 circulator (07-08 section), unmounted
Ratings (as published by PB Heat):
| Model | Input MBH | Output MBH | Net Rating Water MBH | Efficiency | Ship Wt (lb) | Boiler Code No. (Nat / LP) |
|---|---|---|---|---|---|---|
| GM-e-05 | 215 | 182 | 158 | AFUE 84.2% | 428 | 05501 / 05505 |
| GM-e-06 | 268 | 226 | 197 | AFUE 84.0% | 503 | 05601 / 05605 |
| GM-07 | 342 | 275 | 239 | Thermal efficiency 80.3% | 568 | 05741 / 05743 |
| GM-08 | 399 | 320 | 278 | Thermal efficiency 80.3% | 641 | 05841 / 05843 |
Heating capacity and AFUE ratings are based on U.S. Government test; output rating and combustion efficiency determined in accordance with AHRI requirements. Optional circulators, 50 or 80 PSI relief valves and the GM-07/08 vent damper are in the Series GM Optional Equipment checklist on this page.
Order codes, complete water package (as listed by PB Heat; include all applicable stock codes on the order):
| Model | Boiler Code No. (Nat / LP) | Draft Hood | Trim | Vent Damper |
|---|---|---|---|---|
| GM-e-05 | 05501 / 05505 | 90995 | 90991 | 90611 |
| GM-e-06 | 05601 / 05605 | 90996 | 90991 | 50167 |
| GM-07 | 05741 / 05743 | 90997 | 90991 | — (ships less vent damper) |
| GM-08 | 05841 / 05843 | 90997 | 90991 | — (ships less vent damper) |
Lead time is confirmed when we quote.
Documents: Series GM Catalog | Series GM Suggested Specifications
Image is for illustration only. Refer to the product spec sheet for exact dimensions and configuration, and confirm with Kingsway Marketing LLC before you request a quote.
Product selection, sizing and code compliance remain the responsibility of the design professional and the authority having jurisdiction.
Share