PB Heat
PB Heat Series CC Commercial Power Burner Boiler, Oil, Gas or Gas/Oil, 364 to 2,165 MBH
PB Heat Series CC Commercial Power Burner Boiler, Oil, Gas or Gas/Oil, 364 to 2,165 MBH
Burner Equipment
Choices from this burner's own PB Heat page. Standard items are already included; change only what the job needs. Your selections are added to the boiler's SKU as one takeoff line.
Series CC Optional Equipment
View listOptional equipment PB Heat lists for this series. Check the items you need; they are added to the boiler's takeoff line with their PB Heat code numbers.
Couldn't load pickup availability
The PB Heat Series CC is a commercial cast iron power burner boiler supplied packaged, as an assembled block or as individual sections, with forced draft venting, for steam or hot water, with oil, gas or gas/oil burners and optional tankless coils.
Standard equipment (as listed by PB Heat):
- Cast iron, wet-base sections, factory tested for 80 PSI working pressure (water); 15 PSI working pressure (steam)
- Burner mounting plate with insulation block; front and rear flame observation ports
- Steel angle floor rails; ceramic fiber rope seal between sections; target walls (3-6 sections)
- Water: 40 PSI ASME safety relief valve, temperature pressure gauge, operating control L4006A, limit control L4006E manual reset
- Steam: 15 PSI safety relief valve, steam pressure gauge, operating and limit pressure controls
Ratings (as published by PB Heat):
| Size | Oil GPH | Oil Input MBH | Gas Input MBH | Gross Output MBH | Net Steam sq ft | Net Steam MBH | Net Water MBH | Boiler H.P. | Ship Wt (lb) |
|---|---|---|---|---|---|---|---|---|---|
| 03 | 2.6 | 364 | 375 | 308 | 963 | 231 | 268 | 9.2 | 1275 |
| 04 | 3.6 | 504 | 520 | 421 | 1316 | 316 | 366 | 12.5 | 1612 |
| 05 | 5.0 | 700 | 722 | 587 | 1825 | 441 | 510 | 17.5 | 1949 |
| 06 | 6.5 | 910 | 938 | 762 | 2382 | 572 | 663 | 22.8 | 2301 |
| 07 | 7.9 | 1106 | 1140 | 924 | 2888 | 694 | 803 | 27.6 | 2641 |
| 08 | 9.3 | 1302 | 1342 | 1087 | 3398 | 815 | 945 | 32.5 | 2988 |
| 09 | 10.8 | 1512 | 1559 | 1262 | 3947 | 947 | 1097 | 37.7 | 3224 |
| 10 | 12.2 | 1708 | 1761 | 1424 | 4506 | 1081 | 1238 | 42.5 | 3674 |
| 11 | 13.6 | 1904 | 1963 | 1587 | 5071 | 1217 | 1380 | 47.4 | 4013 |
| 12 | 15.0 | 2100 | 2165 | 1750 | 5635 | 1352 | 1522 | 52.3 | 4378 |
Variants cover the boiler less burner and with each factory-matched burner listed by PB Heat (burner carton with standard UL operating mode). Packaged (factory assembled) construction, burner motor voltages, combustion controls, FM / CSD-1 operating modes and other burner options are available as options for each size. The domestic water coil and barometric draft dampers PB Heat lists for this series are in the Series CC Optional Equipment checklist on this page.
Burner models by size (as published by PB Heat; "n/a" means not offered):
| Burner | 03 | 04 | 05 | 06 | 07 | 08 | 09 | 10 | 11 | 12 |
|---|---|---|---|---|---|---|---|---|---|---|
| Oil: Beckett | CF500 | CF500 | CF800 | CF1400 | CF1400 | n/a | CF2300 | CF2300 | CF2500A | CF2500A |
| Oil: Carlin | 201 CRD-PA | 301 CRD-PA | 301 CRD-PA | 702 CRD | 702 CRD | 702 CRD | 702 CRD | 801 CRD | 801 CRD | 801 CRD |
| Oil: Power Flame C | n/a | CR1-O | CR1-O | CR1-O | CR2-OA | CR2-OA | CR2-OA | CR2-OA | CR2-OA | CR2-OB |
| Gas: Beckett | CG10 | CG10 | CG10B | CG10B | CG15 | CG15 | CG25 | CG25 | CG25 | CG25 |
| Gas: Power Flame J | JR15A-10 | JR15A-10 | JR30A-10 | JR30A-10 | JR30A-12 | JR50A-15 | JR50A-15 | JR50A-15 | n/a | n/a |
| Gas: Power Flame C | n/a | CR1-G-10 | CR1-G-10 | CR1-G-12 | CR2-G-15 | CR2-G-15 | CR2-G-15 | CR2-G-15 | CR2-G-20A | CR2-G-20B |
| Gas/Oil: Power Flame C | n/a | CR1-GO-10 | CR1-GO-10 | CR1-GO-12 | CR2-GO-15 | CR2-GO-15 | CR2-GO-15 | CR2-GO-15 | CR2-GO-20A | CR2-GO-20B |
Lead time is confirmed when we quote.
Documents: Series CC Catalog | Series CC Suggested Specifications
Image is for illustration only. Refer to the product spec sheet for exact dimensions and configuration, and confirm with Kingsway Marketing LLC before you request a quote.
Product selection, sizing and code compliance remain the responsibility of the design professional and the authority having jurisdiction.
Share