Water Closet and Lavatory Carrier Selection Guide

A water closet or lavatory that hangs off the floor is only as solid as the carrier behind the wall. The carrier is a specified structural assembly, not a generic bracket. If the load rating, the orientation, or the connection is wrong, the fixture will not land on the rough-in, and the wall will not hide the problem. This guide covers how to select a water closet carrier and a lavatory carrier from the products Kingsway Marketing LLC actually represents, and how to keep that selection aligned with the drawings.

The Wade carriers collection includes the 311 horizontal adjustable water closet support, plus the 311HD heavy-duty, 311XH extra-heavy, and 311XB bariatric versions. It also includes the 401 urinal carrier and the 520 lavatory carrier with concealed arms. Fixture carriers are commonly specified under ASME A112.6.1M. Use that as a general reference, then confirm the load rating, orientation, and connection on the product page and the Wade spec sheet.

Water closet carriers: start with the series, then the rating

The 311 is a horizontal, adjustable, siphon-jet water closet support. It is regularly furnished as a rigid system with no-hub connections, complete with a painted cast iron right-hand, left-hand, or double main fitting, a 2-inch vent, an adjustable gasketed faceplate, and universal floor-mounted foot supports. On Kingsway Marketing LLC, you select the configuration on the product page so the carrier arrives ready for the fixture shown on the drawings.

Load rating is the first fork in the road. The standard 311 is listed at a 300-pound ASME load rating. The 311HD is the heavy-duty version, listed at 500 pounds. The 311XH is the extra-heavy version, listed at 750 pounds. The 311XB is the bariatric version, listed at 1,000 pounds. Those ratings are not interchangeable. If the specification names 311HD, 311XH, or 311XB, order that variant. Do not substitute a standard 311 and hope the wall backing will make up the difference.

Orientation and fitting style come next. A right-hand, left-hand, or double main fitting has to match the piping layout behind the wall. So does the vent connection. If you guess at the handing, the closet will sit correctly in plan and the piping will not. Read the riser and the carrier detail together, then select the fitting on the product page.

The faceplate and foot supports are part of the regularly furnished assembly, but the finished-wall dimension still has to be checked. Carriers are adjustable for a reason. Confirm the rough-in and the dimension from the faceplate to the finished wall against the fixture and the architectural detail. If a project needs a special option, such as a flush-valve support or vandal-resistant hardware, those are requested as a quote rather than assumed to be in the box.

Lavatory and urinal carriers are different products

A water closet carrier will not support a lavatory, and a lavatory carrier will not support a water closet. The 520 is a concealed-arm lavatory carrier, regularly furnished as a single lavatory carrier with round uprights, rectangular base feet, cast iron concealed arms, and non-slip locking devices. Header couplings allow vertical adjustment, and a tie rod allows horizontal adjustment for different lavatory widths. The arms are meant to disappear in the finished wall, with enough of the sleeve left exposed after the wall is completed for a proper installation. Follow that detail. A carrier set too deep or too proud of the wall is hard to correct after tile is in place.

The 401 is a urinal carrier, selected when the specified urinal is carrier-mounted rather than hung on a backing board alone. Use the 401 product page to match the configuration to the urinal on the drawings. If a restroom has closets, lavatories, and urinals, you will often have three carrier types on the same takeoff. That is expected. It is not duplication.

Wheelchair or accessible lavatory installations can require a different arm or leveling arrangement than a standard 520. If the documents call for that option, request it as a quote and do not assume the standard concealed-arm package covers it.

How to specify a carrier without leaving a gap

Work through each fixture on the restroom sheet as its own line item:

  • Identify the fixture type: water closet, lavatory, or urinal.
  • Read the specified carrier series, including HD, XH, or XB on closet supports.
  • Confirm the ASME load rating on the product page against the specification.
  • Select handing, connection, and, on closet carriers, the no-hub fitting that matches the piping.
  • Check finished-wall dimensions, arm or faceplate adjustment, and any quoted options.
  • Confirm the assembly on the Wade spec sheet before you request a quote.

Do not borrow a closet carrier rating to justify a lavatory installation, and do not use a lavatory carrier behind a closet because it is already on the truck. Behind-the-wall equipment is difficult to change after the wall is closed. The inexpensive moment to get the rating and the handing right is now, on the takeoff.

Related restroom work that should be taken off at the same time

Carriers are only one part of a commercial restroom takeoff. Floor drains, cleanouts, and finishes in the same room should be reviewed while the carrier sheet is open, because the same drawings usually show all of them. A closet carrier does not replace a floor drain, and a finished wall line can affect both the carrier rough-in and a nearby cleanout cover. Take them off together, but specify them as the products they are. If the restroom also needs a floor drain or an adjustable cleanout, use the floor-drain and cleanout collections rather than hanging those decisions on the carrier line item.

When you are ready to request a quote, run the drainage takeoff checklist. If a load rating, a handing, or a quoted option is unclear, contact us or request a quote. Get it right the first time.

Back to blog