Slope-to-Drain and Floor Integration for Stainless Steel Drainage

A stainless drain can be the right body and still leave standing water on the floor. Washdown and process waste only leave the room if the finished floor delivers them to the opening, and if the body itself carries them to the outlet. Those are two different slopes, and the project's design team has to design them to work together. This article is for specifying engineers, contractors, and food or beverage facility owners who need the drain and the floor to work as one assembly.

Kingsway Marketing LLC represents the Kusel stainless steel drainage catalog used in food and beverage processing, pharmaceutical and other process rooms, commercial kitchens, and washdown areas. Confirm the exact configuration on the product page and the manufacturer spec sheet before you request a quote. The project's design team (the engineer of record) and the installer determine the floor pitch, the drain location, and the installation detail.

The floor slope and the drain pitch are not the same thing

The finished floor has to fall toward the drain openings. A point drain, a floor sink, or a trough only collects what actually reaches its rim. If the slab is flat, or if it pitches away from the body, water ponds at equipment legs, along walls, and in low spots that the drain cannot see. The floor pitch is determined by the project's design team (the engineer of record) and carried out by the installer. It belongs on the drawings, and it is not a property of the drain catalog number.

The drain body has its own interior geometry. On a Kusel Classic trench drain, that geometry is a V-bottom sloped at 1/4 inch per foot or 1/8 inch per foot, so water and solids move toward the outlet instead of sitting in the channel. A correctly pitched trench will not fix a floor that does not slope to the run, and a well-sloped floor will not empty a channel that was ordered without the pitch the layout requires.

Point drains, sinks, and troughs collect only what the floor brings them

Use a Kusel KE drain when the drawing shows a stainless floor drain at a single collection point. The standard KE body is a 12-inch top with a 6-inch body depth. A 4-inch body is available when space is limited, and 8-inch, 10-inch, and 12-inch bodies are available when the floor is thicker or a deeper sump is required. Outlets on the standard KE body are offered from 2 inch through 10 inch in Schedule 10 or Schedule 40. Keep the body depth and the outlet together in the takeoff, because both have to fit the slab and the pipe below it.

Kusel states that all KE-Series square-top floor drains are USDA accepted and NSF listed. On Kusel's NSF information, the KE Series floor-level cover is listed as Special Duty in accordance with ASME A112.6.3/CSA B79.3, certified for outlet sizes 2 inch to 4 inch. Special Duty is listed there as a 10,000-pound safe live load. That statement is written for square-top KE floor drains and for those outlet sizes. Confirm the marking on the product page and the spec sheet for the exact unit you are ordering, including a round-top, side-outlet, or catch-basin body.

A Classic floor sink is a deeper receptor under equipment, not a substitute for a KE drain. Classic sinks are 14-gauge 304 stainless, with four setting tabs, two on each side, and they are offered with a 4-inch Schedule 40 outlet or a 6-inch Schedule 10 outlet. Order the sink with a basket, a strainer, or both when the equipment detail shows solids in the waste stream. A floor trough is the shorter run under a line of equipment. Troughs are constructed of 12-gauge 304 or 316L stainless with leveling tabs and bead-blasted welds. In each case, the project's design team and installer still have to pitch the finished floor to the rim.

Read the trench pitch, depth, and outlet as one layout

Kusel Classic trench drains are built from a 12-gauge 304 or 316L body, shipped completely welded, with a standard industrial finish and sandblasted welds. A pair of setting tabs is located every 24 inches. The Classic line is a V-bottom, offered in 4-foot increments up to 24 feet, with center or end outlets and an open grate or a solid grate. Custom trenches can be specified with a V-bottom, flat bottom, or U-bottom, in widths from 9-1/4 inches to 18 inches, and in other lengths when the layout requires it.

Pitch and length decide how deep the channel becomes at the outlet, and that depth has to fit the slab and the connecting pipe. Kusel measures starting depth from the top of the trench to the starting tangent of the profile. On Classic units, the shallow-end depth is 3-5/8 inches. A 4-foot, 9-1/4-inch-wide Classic trench with 1/4-inch-per-foot pitch and a center outlet, for example, starts at 3-5/8 inches and reaches 4-1/8 inches at the deepest point, and it uses a 3-inch Schedule 40 outlet. On the Classic configurations Kingsway Marketing LLC offers, a 12-inch-wide trench uses a 4-inch Schedule 40 outlet, and a 14-1/2-inch-wide trench uses a 6-inch Schedule 40 outlet. Record width, length, pitch, starting depth, outlet size, and whether the outlet is at the center or the end, then confirm those values on the spec sheet for that exact unit. A longer run at the same pitch gets deeper at the outlet. If the slab cannot accept that depth, the design team should change the layout, the channel pitch, or the outlet location before the body is built, not after it is in the floor.

The Classic V-bottom trench is NSF-listed in accordance with ASME A112.6.3. Kusel's Classic sheet lists the solid cover as Special Duty and the bar grate as Medium Duty, and it states that bar grating is not recommended for forklift traffic. That listing applies to the Classic V-bottom. Do not assume a flat-bottom or U-bottom custom trench carries the same marking.

When the outlet cannot leave through the bottom

A bottom outlet is not always possible. If the slab, a thickened floor, or the elevation of the connecting pipe will not accept a bottom outlet, order a body that is built for a side outlet rather than turning a standard body in the field. Kusel offers a KE side-outlet drain as a 12-inch top with a 6-inch body depth and 2-inch through 4-inch outlets in Schedule 10 or Schedule 40, in 304 or 316L, with a square or round top. Custom trench drains can be specified with a side outlet, or with other custom or multiple outlet locations, when elevation is the problem along a run. If the documents name a side-outlet or a catch-basin body, stay with that body. Do not substitute a side outlet for a standard KE drain or a Classic trench just because the top size looks familiar.

Set the drain so the finished floor can meet it

The body has to be set to the finished elevation, held stable while the slab is placed, and detailed for the floor system actually being used. The installer uses the setting tabs to hold the rim at the correct elevation so the floor can be pitched to the opening rather than stepping up or down at the metal. Classic trenches include a pair of setting tabs every 24 inches. Classic floor sinks include four setting tabs, two per side.

When a waterproof membrane is installed in the floor, Kusel offers a membrane clamp ring: a fully welded bottom ring and a bolt-on top ring. A tack-welded setting ring is a different option, used for added support. In tile or brick floors, where concrete cannot be worked fully into the integral concrete anchor lip, Kusel specifies a reinforcement ring. These accessories are not automatic on every body. Kusel notes that a setting ring and a membrane clamp ring are not available options on the KE side-outlet drain. If the floor system requires a clamp ring or a reinforcement ring, select a body that can accept it, and show it on the takeoff.

The finished surface still has to meet the rim cleanly, whether that surface is concrete, tile, or another specified floor finish. The installation detail should be confirmed by the engineer of record and follow the manufacturer instructions. A gap, a trip edge, or a pocket at the perimeter is a place for water and waste to collect, and it is much harder to correct after the floor is down.

Choose the grate for the traffic that will cross the opening

The grate is the walking and rolling surface of the drain, and it has to match the traffic in the room. Classic trenches are offered with an open grate or a solid grate, with or without a strainer. The open grate uses 10-gauge bearing bars on 1-1/2-inch centers and 8-gauge side banding bars, continuously welded. The solid grate is 1/2-inch plate with a 1/2-inch drain gap and continuously welded feet. Select the grate the documents name.

Load class at the grate is not interchangeable across the catalog. The Classic V-bottom solid cover is listed Special Duty and the bar grate Medium Duty, and bar grating is not recommended for forklift traffic. Kusel's NSF information lists Medium Duty as a 1,984-pound safe live load and Special Duty as 10,000 pounds, under ASME A112.6.3/CSA B79.3. The Kusel KEM drain is a different, shallower body, furnished in 316L with an 8-inch top and a 2-inch body depth, and it is NSF-listed as Medium Duty in accordance with ASME A112.6.3 for outlet sizes 2 inch to 3 inch. Kusel describes the KEM drain for lower-traffic, pedestrian areas. Do not use a KEM body where the documents require a KE drain, and do not assume a Medium Duty grate will take forklift traffic.

Confirm the layout before the body is in the slab

Once the drain is encased, a floor that pitches the wrong way, a trench that is too deep for the outlet, or a missing membrane clamp is expensive to unwind. If you are still selecting the drain type or the alloy, start with our guides to choosing a commercial floor drain and stainless steel drains in food processing facilities, then come back to the channel pitch and setting details on this page.

Send the drawings, the specification, or the list. We work alongside the design team and installer, and we are glad to help with product selection, submittals, and matching the Kusel series, body depth, outlet, grate, and accessories to the floor layout they have set. That includes making sure a standard KE body is not standing in for a side-outlet drain, or a Classic V-bottom trench for a custom profile. If you would like a hand choosing the right drain or requesting a quote, contact us. Get it right the first time.

Back to blog